70% discount - Free shipping worldwide

Sale!

Series MS2 Magnesense® II Differential Pressure Transmitter

Monitors Pressure, Air Velocity & Air Flow, BACnet/Modbus® Communications

Manufacturer:

SKU: MS2

MPN: MS2

List Price: 200.000 VND

Today's Price: 100.000 VND

Product Details
The SERIES MS2 Magnesense® II Differential Pressure Transmitter combines the proven stable Hall Effect sensing technology of our original Series MS with additional features to reduce installation time and simplify ordering. In this second generation transmitter, we have added additional field selectable pressure ranges so that each model can have four selectable ranges along with four additional bidirectional ranges. When using the pluggable integral display or the portable remote display tool, both Metric and English engineering units can be selected via on board dip switches. Dual current and voltage outputs allow users to simultaneously take either a current or voltage output to their building controller and have a local test circuit for verification of the output reading. The voltage output can be selected to be either 0 to 5 VDC or 0 to 10 VDC, while the current is always 4 to 20 mA. Both the current and voltage output can also be inverted. The MS2 can also be ordered with either a BACnet® or MODBUS® Communications protocol output that will allow the transmitters to be daisy-chained together.

Like the original Series MS, the second generation transmitter can be used as a linear pressure output or a linear velocity output with the square root extraction done in the transmitter. Additional parameters have been included to expand the square root capability to include flow measurements.

BACnet® and Modbus® Communications protocol recommend limiting the number of nodes in any segment to 32. Therefore, the transceiver may be rated at one unit load. Fractional loads are also acceptable. The MS2 accounts as an eighth of a load on the MSTP network.

Features:
• Field selectable ranges and output signal reduce inventory and the chances of ordering an incorrect part
• BACnet® or Modbus® serial communications reduce wiring cost by daisy-chaining the transmitters
• Our integral field-upgradeable display or plug-in remote display tool save upfront material cost and allow for local viewing of measurements

Approvals:
• BTL Certificate
• CE Approval
• GOST-R Approval
• RoHS Letter of Compliance

Applications:
• Duct Static Pressure in Commercial Buildings
• Fan Proving
• Filter Monitoring in Air Handler Units
• Building Pressure in Pharmaceutical-Semi-Conductor Clean Rooms
• Air Velocity/Flow in VAV Systems

Specifications:
Supported Baud Rates:9600, 19200, 38400, 57600, 76800, 115200.
Data Size:8.
Parity:None.
Stop Bits:1
Service:Air and non-combustible, compatible gases.
Wetted Materials:Consult factory.
Accuracy:±1% FS for 0.15 in w.c. (40 Pa), 0.25 in w.c. (50 Pa), 0.5 in w.c. (100 Pa), 2 in w.c. (500 Pa), 3 in w.c. (750 Pa), 5 in w.c. (1250 Pa), 10 in w.c. (2 kPa), 15 in w.c. (3 kPa), 25 in w.c. (5 kPa), 28 in w.c. (6.975 kPa); ±2% FS for 0.1 in w.c. (25 Pa), 1 in w.c. (250 Pa), and all bi-directional ranges.
Stability:±1% / year FSO.
Temperature Limits0 to 150°F (-18 to 66°C).
Pressure Limits:1 psi max., operation; 10 psi burst.
Power Requirement:10 to 35 VDC (2-wire), 17 to 36 VDC or isolated 21.6 to 33 VAC (3-wire).
Output Signals:4 to 20 mA (2-wire), 0 to 5 VDC, 0 to 10 VDC (3-wire).
Response Time: Adjustable: 0.5 to 15 sec. time constant. Provides a 95% response time of 1.5 to 45 seconds.
Zero & Span Adjustments:Digital push button.
Loop Resistance:Current Output: 0 to 1250 Ω max;Voltage Output: Min. load resistance 1 kΩ.
Current Consumption:40 mA max.
Display (optional):5 digit LCD.
Electrical Connection:3-wire removable European style terminal block for 16 to 22 AWG.
Electrical Entry:1/2" NPS thread.
Process Connection:3/16" ID tubing (5 mm ID); Max. OD 9 mm.
Enclosure Rating:IP66.
Mounting Orientation:Diaphragm in vertical position.
Weight:8.0 oz (230 g).
Agency Approvals:BTL, CE.
Top Sellers
Sale

Series V8 Flotect® Vane Operated Flow Switch

Field Adjustable – 1 to 6 Inch Pipe, Leak Proof Body

100.000 VND
200.000 VND

Quick Add

Sale

WDPM-Differential Pressure Modules

Wireless, Measure Differential Pressure, Air Velocity, &Flow

100.000 VND
200.000 VND

Quick Add

Sale

ULTRASONIC LEVEL TRANSMITTER ULT

Explosion-Proof, Mapping Software, 3˝ (76.2 mm) Measuring Column

100.000 VND
200.000 VND

Quick Add

Sale

Series V4 Flotect® Vane-Operated Flow Switch

Field Adjustable – Dependable Protection Against Flow Variation or Stopping in Pipelines for Fluids, Gases and Flowing Solids

100.000 VND
200.000 VND

Quick Add

Sale

Series TTW Weatherproof Immersion Temperature Transmitter

Pt100 RTD, PC Programmable Transmitter

100.000 VND
200.000 VND

Quick Add

Sale

Ultrasonic Energy Meter (Series TUF)

Flow & Temperature Monitoring Capability, Modbus® & BACnet Communication

100.000 VND
200.000 VND

Quick Add

Sale

Series TE Duct and Immersion Building Automation Temperature Sensor

Available up to 18″ Probe Length, Thermistor or RTD Outputs

100.000 VND
200.000 VND

Quick Add

Sale

Series TE-A Averaging Temperature Sensors

Available in 6′, 12′ and 24′ Lengths

100.000 VND
200.000 VND

Quick Add

Sale

Series TE-E/N Wall Mount Temperature Sensor

Discrete Wall Mount Housing

100.000 VND
200.000 VND

Quick Add

Sale

Series TE-W Wall Mount & TE-WSS Stainless Steel Wall Plate Temperature Sensors

Discrete Wall Mount Housing vs. Screw Terminal Connection, Suitable for Wash Down Applications

100.000 VND
200.000 VND

Quick Add